Load Centers

GE Load Centers
Industrial Systems – Distribution

GE Load Centers

  • Q Line Circuit Breakers
    • PowerMark Gold Main Circuit Breakers
    • Arc Fault Circuit Interrupter
    • CB3 Ground Fault Circuit Interrupter
    • Switching Neutral
    • HID Lighting Breaker
    • High Magnetic Breaker
    • Molded Case Switch
    • Surge Arrester
    • TQ Breaker
  • PowerMark Gold Load Centers
    • PowerMark Gold load centers lower your costs by making installation
      faster and easier, increasing application flexibility and reducing
      inventory requirements. At the same time, they deliver obvious and
      significant advances in design, function and quality.

      • Exclusive GE lifetime warranty
      • UL Listed (Panelboards No. 67)
      • Suitable for Use as Service Entrance Equipment when installed in accordance with National Electrical Code
      • 60°C/75°C Conductor Rating
      • Single phase, 40-225A, 2-42 circuits
      • Main lug models field convertible to main breaker
      • Main breaker 22kAIC standard – factory installed
      • All load centers top or bottom feed
      • Indoor and outdoor rated enclosures
      • Indoor fronts combination surface/flush
      • Copper bus standard
      • Split neutrals extend the full length of the interior for ease of wiring
      • Entire main lug line converts easily to main breaker
      • Combination surface/flush front with spring-reinforced pan
      • Combination slotted/Robertson square-drive screws on neutral, ground, front and breaker lugs
      • Front packed in inner carton for added protection
      • Field installable feed-through lugs up to 200A
      • Straight-through main wiring
      • Main breaker is clearly marked and circuit numbers are stamped on front
      • Isolated ground bar is available
      • Compact box maintains optimum wire-bending space
  • PowerMark Gold and Plus Load Centers
  • Q Line Plug-in Circuit Breakers
    • UL Listed (Molded Case Circuit Breakers No. 489)
    • Federal Government Specification Qualified (WC-375B)
    • 60°C / 75°C Conductor Rating
    • Quick Make, Quick Break
    • Box Type Terminals
  • Special Purpose Circuit Breakers
    • 60°C / 75°F Conductor Rating
    • Box Type Terminals
    • Quick-Make, Quick-Break
    • Multi-pole Breakers Incorporate Internal Common Trip
  • PowerMark Gold and Plus Single-Phase Load Centers – Main Lug and Convertible Load Centers
    • UL Listed (Panelboards No. 67)
    • 60°/75°C Conductor Rating
    • Suitable for Use as Service Entrance Equipment when Installed in Accordance with the National Electrical Code
    • 22kAIC RMS symmetrical, Except Where Noted
    • 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down.
  • PowerMark Gold and Plus Main Breaker Load Centers – Main Breaker Factory Installed
    • UL Listed (Panelboards No. 67)
    • 60°C/75°C Conductor Rating
    • Suitable for Use as Service Entrance Equipment when Installed in Accordance with the National Electrical Code
    • 22kAIC RMS symmetrical, Except Where Noted
    • 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down.
  • PowerMark Plus Three-Phase Load Centers – Main Circuit Breaker or Main Lugs Factory Installed
    • UL Listed (Panelboards No. 67)
    • 60°/75°C Conductor Rating
    • Suitable for Use as Service Entrance Equipment when Installed in Accordance with the National Electrical Code
    • 22kAIC RMS symmetrical Short-circuit Rating Standard
    • 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down.
  • PowerMark Gold Load Centers—Specialty Panels
    • Suitable for use in accordance with Article 702 of the National Electrical Code, ANSI/NFPA 70
    • Single-phase, 2 interlock 60A or 30A main breakers, 8 circuits max.
    • Safety and convenience when using a generator – 14,000 peak wattage, 11,520 continuous load, 48 amps at 240 volts.
    • Maintains power to such critical circuits as those for furnace, pump, refrigerator, lights.
    • Connected dual breaker mechanism ensures that only one source is active at a time.
  • PowerMark Gold Meter Socket Load Centers With Bonded Neutrals
  • PowerMark Gold and Plus Circuit Breaker Load Centers – Field Installed Accessories
  • Load Centers and Meter Socket Load Centers

For more information on GE Load Centers, please e-mail our sales dept at sales@jostfewkes.com or utilize our Quotation Request Form.

top